Victron Energy Skylla-TG 24/50 GMDSS 120–240V Battery Charger – SDTG2400504

Victron Energy Skylla-TG 24/50 GMDSS 120–240V Battery Charger – SDTG2400504

Regular price £858.07 GBP
Regular price £1,362.01 GBP Sale price £858.07 GBP
Sale Sold out
Taxes included. Shipping calculated at checkout.

Product Overview

The Victron Energy Skylla-TG 24/50 GMDSS is a professional 24V, 50A battery charger and power supply designed for demanding marine applications, particularly Global Maritime Distress and Safety System (GMDSS) installations. Combining advanced battery charging technology with integrated monitoring and alarm functionality, it provides a dependable power management solution for critical onboard electrical systems.

With a universal AC input range of 90–265V, the Skylla-TG can operate from a wide variety of AC supplies. Its intelligent three-stage charging system, temperature compensation and battery voltage sensing help maintain accurate charging performance and support long-term battery reliability.

The GMDSS version is designed to provide the monitoring and alarm information required by marine safety installations. A compatible VE.Net GMDSS digital panel can display system information and alarms, with the panel available separately.

GMDSS Monitoring and Marine Applications

The Skylla-TG GMDSS is designed to connect directly to both the vessel's battery system and GMDSS equipment. It provides monitoring and alarm information for the connected installation, helping operators monitor battery condition and system performance.

When connected to the optional VE.Net GMDSS panel, the system can display important battery information, alarms and estimated battery time remaining during a power supply failure. The panel connects using a standard eight-wire UTP cable and must be purchased separately.

This makes the charger particularly suitable for commercial vessels, professional marine electrical systems, communication equipment and installations where reliable emergency power is essential.

Intelligent Three-Stage Charging Technology

The Skylla-TG uses a microprocessor-controlled IUoUo three-stage charging process, incorporating bulk, absorption and float charging stages. This helps recharge batteries efficiently before maintaining them at an appropriate voltage.

The absorption voltage is 28.5V DC and the float voltage is 26.5V DC. Charging voltage can be adjusted to suit compatible sealed and flooded battery systems.

An included external battery temperature sensor enables automatic temperature compensation. As battery temperature increases, the charging voltage is reduced to help prevent overcharging, excessive gassing and premature battery deterioration.

The integrated battery voltage sensing facility compensates for voltage losses across battery cables by measuring voltage directly at the battery terminals. This helps ensure the batteries receive the correct charging voltage.

Dual Battery Outputs

The charger provides one full-rated 50A charging output and a separate auxiliary output limited to approximately 4A. The auxiliary output is intended for maintaining a second battery bank, such as a vessel's starter battery.

The two isolated outputs allow separate battery banks to be charged from a single charger, making the unit particularly useful in marine installations with dedicated starting and service batteries.

Power Supply Capability and Protection

In addition to battery charging, the Skylla-TG can operate as a DC power supply. Forced cooling supports operation under demanding charging conditions, while integrated protection includes output short-circuit protection, battery reverse-polarity detection, overvoltage protection and overtemperature protection.

The aluminium enclosure is finished in Victron blue and has an IP21 protection rating. Its construction and electrical characteristics make it suitable for professional installation in appropriately protected marine electrical environments.

Technical Specifications

The Victron Skylla-TG 24/50 GMDSS has a nominal battery voltage of 24V DC and a maximum main charging current of 50A. Its AC input voltage range is 90–265V AC, with an operating frequency of 45–65Hz and a power factor of 1.

The charging algorithm is IUoUo three-stage charging, with an absorption voltage of 28.5V DC and a float voltage of 26.5V DC. The charger includes a temperature sensor, battery voltage sensing capability and a separate auxiliary charging output of approximately 4A.

The operating temperature range is -40°C to +50°C, with maximum non-condensing humidity of 95%. The enclosure has an IP21 protection rating and is manufactured from aluminium.

The unit measures approximately 485mm high, 250mm wide and 147mm deep, with a weight of approximately 6kg.

The AC connection is supplied with a three-wire 2.5mm² cable approximately 2 metres long. Two 1.5-metre battery connection cables and a 1.5-metre GMDSS connection cable are also specified.

Installation and Compatibility

The Skylla-TG 24/50 GMDSS is intended for compatible 24V battery systems and professional marine electrical installations. Correct battery configuration, cable sizing, ventilation and installation procedures are important to ensure safe and reliable operation.

The optional VE.Net GMDSS digital panel and its connecting UTP cable are not included and must be ordered separately. The installation should be carried out by a suitably qualified marine electrical installer familiar with GMDSS requirements.

Product Summary

The Victron Energy Skylla-TG 24/50 GMDSS is a high-performance 24V, 50A marine battery charger designed for dependable power management in professional maritime installations. Its universal AC input, intelligent charging technology, dual battery outputs, temperature compensation and integrated GMDSS monitoring functionality make it a comprehensive solution for vessels requiring reliable battery charging and emergency power support.